Ventilator machine is one kind of our anesthesia ventilator, If this could not feed your requirement, just see other anesthesia machine, such as veterinary anesthesia machine, anesthesia ventilator, anesthesia gas machine, portable anesthesia machine.
Introduction of anesthesia machine: Do you want to know the technology of anesthesia machines?...
Display size: 15.6 in diagonal Display type: Active matrix color TFT LCD Display resolution: SVGA resolution, 1366 x 768 Fully electronic control Ventilation type: Blower Ventilation modes: A/C-VCV, A/C-PCV, A/C-PRVC, SIMV-VC, SIMV-PC, SIMV-PRVC, BIPAP, APRV, CPAP, CPAP-VG.
Packaging detail:Standard export package Delivery detail:within 7-10 workdays after receipt of payment |
Adjustable noninvasive ventilation ICU Ventilator high flow oxygen therapy Breathing Machine MSLVM30
Electrial Interface
Nurse call, USB, NET, RS232, VGA
Interface Type
Main patient outlet: ISO 22M/15F
Oxygen inlet: DISS or NIST male
Display
Display size:
15.6 in diagonal
Display type:
Active matrix color TFT LCD
Display resolution: SVGA resolution, 1366 x 768
Controls
Fully electronic control
Ventilation type: Blower
Ventilation modes:
A/C-VCV, A/C-PCV, A/C-PRVC, SIMV-VC, SIMV-PC, SIMV-PRVC, BIPAP, APRV, CPAP,
CPAP-VG.
Special functions:
manual breath, 02 therapy, standby, screen-lock, inspiratory hold, expiratory hold, sigh,
ATC, PCVR, PPS, Compliance, p0.1, calibrate, nebulizer, 02 suction.
Patient types:
Adult/Pediatric/Neonate
Patient height:
Adjustable
Monitoring
Real-time waveforms:
Paw, Flow, Volume, EtCO2, SPO2
Optional: CO2, SPO2 (related parameters)
Loops:
P-V, V-Flow, Flow- P
Trends: 1s, 5s,1min,10min, 30min, 60min
Tidal volume:
5 to 2000mL
PEEP/CPAP:
0 to 30 cmH2O
Oxygen:
21 to 100%
l:E ratio:
1:10 to 4:1.
Inspiratory time(T): 0.2 to 5s
Flow trigger:
0.2 to 15 l/min .
Pressure trigger.
-0.5 to -20cmH2O
Pressure control:
5 to 90 cmH2O, added to PEEP/CPAP
Pressure support:
0 to 90 cmH2O, added to PEEP/CPAP
Pressure ramp:
0to2s
Expiratory trigger sensitivity (ETS):
OFF, 5 to 90 % of inspiratory peak flow
Peak flow Spontaneous:
> 210 L/min
Electrical and gas supplies
Input voltage:
100to 120V ~ +10 %, 50/ 60Hz AC or 24 VDC+10 %
Power consumption:
50 W typical
Protection class:
Class I
Backup battery:
2 batteries(5200mAh each)/ hot swappable
Oxygen supply:
280to600kPa(41to87psi),120L/min
Low pressure:
oxygen≤15 L/ min, max. 600 hPa for low pressure
Alarms
Operator-adjustable:
Low/high minute volume, low/high pressure, low/high tidal volume, low/high rate, apnea time, low/high oxygen
Optional:
low/high CO2, low/high SPO2
Special alarms:
Oxygen concentration, disconnection, loss of PEEP, exhalation obstruction, flow sensor, power supply batteries, gas supply
Loudness Adjustable: 1 to 9
Event log:
Storage and display of up to 1000 events with date and time stamp
Physical dimensions
Weight:
< 45.3 kg
Dimensions(WxHxD): Approx. 600x402x415mm